Specifications
P6015A Instruction Manual
1–27
Typical and Nominal Characteristics
This section lists the various typical and nominal characteristics that
describe the P6015A High Voltage Probe.
Nominal characteristics are determined by design and/or inspection.
Nominal characteristics do not have tolerance limits.
Typical characteristics are described in terms of typical or average
performance. Typical characteristics are not warranted.
Table 1–5: Typical Electrical Characteristics
Characteristic Information
Input resistance
100 MW ±2%. See Figure 1–8 for typical input
impedance curve.
Input capacitance ≤3 pF when probe is properly LF compensated. See
Figure 1–8 for typical input impedance curve.
LF compensation range 7 pF to 49 pF
Aberrations 25% p-p for the first 200 ns on a 100 MHz oscilloscope
when used with 10 in (25.4 cm) ground lead.
<10% p-p typical after first 200 ns; ±5% after the first
400 ns.
Temperature coefficient of DC
attenuation
0.006% per degree C
1
Voltage coefficient of DC attenu-
ation
0.018% per kV
Delay time 10 ft cable: 14.7 ns
25 ft cable: 33.3 ns
1
Resistor temperature rose 60_C at 20 kV rms over a 30 minute period.