Command Descriptions
2ā260
TDS Family Oscilloscope Programmer Manual
Trigger
TRIGger:MAIn:PULse:SLEwrate:THReshold:HIGH <NR3>
TRIGger:MAIn:PULse:SLEwrate:THReshold:HIGH?
TRIGger
:
:
PULse
MAIn
:
:
?
<Space>
<NR3>
HIGH
THReshold
SLEwrate
<NR3> is the threshold, in volts.
TRIGGER:MAIN:PULSE:SLEWRATE:THRESHOLD:HIGH 120E-3
sets the upper limit of the pulse slew rate trigger to 120 mV.
TRIGger:MAIn:PULse:SLEwrate:THReshold:LOW
TDS 684A & 7XXA Only
Sets or queries the lower (most negative) limit of the two threshold levels that a
pulse edge must traverse for the slew rate trigger to occur. This command is
equivalent to setting the lower threshold in the Pulse Slew Rate Triggerās
Thresholds side menu item.
Trigger
TRIGger:MAIn:PULse:SLEwrate:THReshold:LOW <NR3>
TRIGger:MAIn:PULse:SLEwrate:THReshold:LOW?
THReshold
TRIGger :
:
PULse
MAIn
:
:
?
<Space>
<NR3>
LOW
SLEwrate
<NR3> is the threshold, in volts.
Group
Syntax
Arguments
Examples
Group
Syntax
Arguments