Appendix A: Specications
Inputs
Measured on one channel, with test signal applied to another
channel, and with the same scale and coupling settings on
each chann el
Frequency range
Crosstalk
100 MHz 100:1
300 MHz 50:1
Channel
to channel
crosstalk,
typical
500 MHz 30:1
Differential
delay,
typical
100 ps between any two channels with the same scale and
coupling settings
1
For denitions, refer to C ompliance Information.(Seepagexi,Compliance information.)