20 21
long periods unattended.
Note When the temperature range has been set successfully
the scheduled parameters will be saved in Powertxt®. These
settings are saved in Powertxt® and will remain until the socket
is reset to its factory settings or the settings are changed by this
method again. If the socket loses external power or is turned off
these parameters are still saved.
Heating Mode
Heating mode is used when Powertx is connected to a
heating device e.g. in winter when the temperature is low and
Powertx might be used to turn on a heater to keep the
room/environment warm. When the room/environment
temperature goes below the minimum set value it will turn the
power (output) ON then when the room/environment
temperature reaches the maximum set value it will turn the
power (output) OFF.
Please send the following SMS command to set the temperature
control parameters for heating mode:
#159#0#MinimumTempValue#MaximumTempValue#
e.g. #159#0#10#20#
When the room/environment temperature drops below 10 degrees
centigrade the power (output) will automatically turn ON and when
the room/environment temperature goes above 20 degrees
centigrade the power (output) will automatically turn OFF.
Cooling Mode
Cooling mode is used when Powertx is connected to a
cooling device e.g. in summer when the temperature is high and
Powertx might be used to turn on an air conditioner to keep
the room/environment cool. When the room/environment
temperature goes above the maximum set value it will turn the
power (output) ON and when the room/environment temperature
reaches the minimum set temperature it will turn the power
(output) OFF.
Please send the following SMS command to set the temperature
control parameters for cooling code:
#159#1#MinimumTempValue#MaximumTempValue#
e.g. #159#1#15#25#
When the room/environment temperature reaches 25 degrees
centigrade the power (output) will automatically turn ON and
when the room/environment temperature drops to 15 degrees
centigrade the power (output) will automatically turn OFF.
5.2. Controlling the Power (Output) by Temperature Range
ON
Please send the following SMS command to turn the control by
temperature range function ON: #159#1#
5.3. Controlling the Power (Output) by Temperature Range
OFF
Please send the following SMS command to turn the control by
temperature range function OFF: #159#0#