18 19
4.2. Controlling the Power (Output) by Time/Day - ON
Once the time/day parameters have been set (see point 4.1) the
function needs to be turned ON.
Please send the following SMS command to turn the control by
time/day function ON: #128#1#
4.3. Controlling the Power (Output) by Time/Day - OFF
Please send the following SMS command to turn the control by
time/day function OFF: #128#0#
4.4. Controlling the Power (Output) by Time Delay – Power
ON
Powertxt® can be set by SMS command so there is a delay in
turning the power (output) ON or OFF.
Note: When the ‘Time Delay’ function is applied the pre-set
‘Time/Day Control’ switching of Powertxt® power (output) will be
over-ridden (e.g. If you send an SMS command to Powertxt® to
turn the power off after 10 minutes and then you send an SMS
command to turn the power off 2 minutes later the ‘time delay’
function will be cancelled as Powertxt® power is now off. This is
also the same if Powertxt® is set to be on between 9am-5pm
Monday to Friday and an SMS command is sent to Powertxt®
to turn it off at 3pm (or by pressing the Power Control button on
the side). To reset these functions they need to be turned on
again by sending #128#1# (see point 4.2.).)
Please send the following SMS command to turn the power
(output) ON after a set number of minutes: #138#1#Minutes#
e.g. #138#1#60#
This will turn the power (output) ON in 60 minutes (1 hour).
Note: Minutes are the parameters to be set and the range is 1-
720. If the minute range is set at 0 the function will be invalid and
the power (output) of Powertxt® will not be changed.
4.5. Controlling the Power (Output) by Time Delay – Power
OFF
Please send the following SMS command to turn the power
(output) OFF after set a number of minutes: #138#0#Minutes#
e.g. #138#0#125#
This will turn the power (output) OFF in 125 minutes (2 hours and
5 minutes).
Controlling the Power (Output) by Temperature
5.1. Setting the Temperature Range Parameters
There are two modes for controlling the power (output) by
temperature, Heating Mode & Cooling Mode. These
parameters have to be set first then you turn the function ON
with another SMS Command (see points 5.2. & 5.3.).
Warning – Do not exceed any voltages as stated in this manual
and only connect to electrically safe and reliable equipment. We
do not recommend you leave a heating/cooling device on for