1
L
N
Open
Close
Com
Power
supply
240V
Motor
Courtesy
lamp
Ground
+ 12V
Com
neg tx FTC
FTC
TD
Com
TB
Com
TD
TBRéflex photocell
Zone 240V
Safety zone, isolated low voltage
Motor
Motor Earth
Mains Earth
Mains Live
Mains Neutral
DateCode Number: Series Model number Draft
TVLink RS868
25/11/13
TVPRP868F08E
1- GENERAL DESCRIPTION
Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit
switch inside or outside the motor, radio receiver section with transmitter channel memorization by
means of internal push button or via radio.
Possibility to connect wired with auto-test control before every closing movement.
Possibility to connect a 240 V
courtesy lamp with variable time from 1 min. to 12 hours (default
1min.)
Plastic housing for external use equipped with clamps.
Possibility of centralized controls for simultaneous control of several appliances.
Possibility to connect external mechanical controls with dynamic push button function and blockage
push button.
2- CONNECTIONS
Description of the connections:
1 Input ground general power supply
2 Input ground motor
3 Input general power supply 240 V
phase
4 Input general power supply 240 V neutral
5 Opening output relay motor contact
6 Output 240 V neutral by means of fuse
(common motor)
7 Closing output relay motor contact
10-11 Output LC 240 V 300 W max. for
courtesy lamp
(only for the version with courtesy light)
12 Positive output 12/15Vdc 80mA
for photocells
13 Safety common contact
14 Negative output for photocells (autotest)
15 FTC input (NC normally closed)
19 Push buttons common for TD
20 Dynamic push-button input (NO normally open)
21 Stop push-button TB (NC normally closed)
22 Push buttons common for TB
24 Antenna ground
25 Antenna pole (wire 8.5cm)
T574.01
TELECO AUTOMATION SRL - Via dell’Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536
www.telecoautomation.com
This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights