Loading...
TELECO AUTOMATION SRL - Via dell’Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com
This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
IT - CENTRALE 24Vdc CON RICEVITORE RADIO PER IL COMANDO DI 1 MOTORE 24Vdc PER
PROFILI ORIENTABILI.
EN - 24Vdc CONTROL UNIT WITH RADIO RECEIVER TO CONTROL ONE 24Vdc MOTOR FOR
ADJUSTABLE SLATS.
FR - CENTRALE 24Vdc AVEC RÉCEPTEUR RADIO POUR LA COMMANDE DE 1 MOTEUR 24Vdc
POUR PROFILS ORIENTABLES.
DE - 24Vdc STEUEREINHEIT MIT FUNKEMPFÄNGER FÜR DIE STEUERUNG VON 1
GLEICHSTROM-MOTOREN (24Vdc) FÜR EINSTELLBARE LAMELLEN.
ES - UNIDAD DE CONTROL 24Vdc CON RECEPTOR RADIO PARA EL CONTROL DE UN MOTOR
24Vdc PARA PERFILES ORIENTABLES.
IT - Ingressi per sensori pioggia e vento.
EN - Inputs for rain and wind sensors.
FR - Entrées pour capteurs de pluie et vent.
DE - Eingänge für Regensensor und Windwächter.
ES - Entradas para sensores de lluvia y viento.
IT - Codice prodotto
EN - Product code
FR - Code du produit
DE - Artikelnummer
ES - Código de producto
IT - Auto-apprendimento necorsa e tempi lavoro.
EN - Limit-switch and working time self-learning.
FR - Auto-apprentissage des ns de course et temps de travail.
DE - Selbstlernen von Anschlag- und Betriebszeiten.
ES - Auto-aprendizaje de interruptores de n de carrera y tiempo de trabajo.
M
M
230Vac
IN
+ 24Vdc
-
+ 24Vdc
-
24Vdc
> 80W
Led
24Vdc
(< 4.5A)
IT - Uscita alimentazione 24Vdc
EN - 24Vdc power supply output
FR - Sortie de alimentation 24Vdc
DE - 24Vdc Stromversorgung Ausgang
ES - Salida de alimentación 24Vdc
M
24Vdc
DOC.: T661.01
TVPLSxxxCS
DATE: 29/04/16
TVPLS868CS
(868.3Mhz)
TVPLS916CS
(916Mhz)
Question and Answer IconNeed help?

Do you have a question about the Teleco TVPLS868CS and is the answer not in the manual?

Overview

This document describes a device designed for automated control systems, specifically for managing shutters, awnings, and similar applications. The device, identified by models TVPLS868CS and TVPLS916CS, operates on a 24Vdc power supply and supports both 868.3 MHz and 916 MHz radio frequencies, respectively.

Function Description

The core function of this device is to receive radio commands from transmitters and control connected motors. It supports various control modes, including manual operation via buttons, automatic commands from multi-button transmitters, and specialized 7/42 channel transmitters. The system can manage up to 16 different radio codes, allowing for individual or group control of multiple devices.

Key functionalities include:

  • Motor Control: The device can open, stop, and close motors. It supports both momentary and continuous operation modes for opening and closing.
  • Radio Code Memorization: Users can program various types of transmitters (1-button, 2 or 3-button automatic, and 7/42 channel) to control the device. The memorization process involves pressing specific buttons on the transmitter and the device's P1 button in a sequence, confirmed by an intermittent sound from the buzzer.
  • Working Time Configuration: For 7/42 channel transmitters, the device allows configuration of the working time. This involves pressing the P1 button multiple times, followed by a command from a memorized transmitter. The system automatically stops after 90 seconds if no further action is taken, or if the maximum working time (90 seconds) is exceeded.
  • Radio Code Deletion: Individual or all memorized radio codes can be deleted. Deleting a single code involves pressing the P1 button multiple times and then pressing the button on the transmitter corresponding to the code to be deleted. Deleting all codes requires pressing P1 multiple times, resulting in a continuous sound from the buzzer.
  • Remote Memorization/Deletion: The device supports remote memorization and deletion of radio codes using a previously memorized transmitter (P3 button). This feature simplifies the management of multiple devices without direct access to each unit.
  • Sensor Integration: The device can integrate with external sensors to enhance automation.
    • Wind Sensor (ANEM4): Detects wind speed and triggers actions based on predefined thresholds (DIPs 3-4). If the wind speed exceeds the threshold, the device can activate an alarm (L2 flashes) and prevent further commands, or even close the connected motor to protect it.
    • Rain Sensor: Detects rainfall. When rain is detected, the device can activate an alarm (L1 ON) and prevent commands that would expose the connected motor to rain, such as opening an awning.
  • End Stop Management: The device includes DIP switches (DIP1 and DIP2) to manage mechanical end stops, preventing the motor from over-running.

Important Technical Specifications

  • Power Supply: 24Vdc
  • Max. Output Power: Max. 4.5 A (24Vdc)
  • Rain Sensor Power Supply: 12 Vdc (max. 100mA)
  • Operating Temperature Range: -20°C to +50°C
  • Working Time: 90 seconds (maximum)
  • Protection Rating: IP54
  • Reception Frequency:
    • TVPLS868CS: 868.3 MHz
    • TVPLS916CS: 916 MHz
  • Radio Memory Capacity (transmitters): 16 codes
  • Dimensions: 115 mm (length) x 85 mm (width) x 65 mm (height)
  • Material: Thermoplastic ABS

Usage Features

  • LED Indicators: The device features LED indicators for power supply (24Vdc IN), output (24Vdc OUT), and various sensor states (e.g., L1 for rain sensor, L2 for wind sensor).
  • DIP Switches: Multiple DIP switches are available for configuring various parameters, including wind sensor thresholds (DIP3, DIP4), and end stop management (DIP1, DIP2).
  • Programming Button (P1): A central P1 button is used for all programming and deletion operations.
  • Buzzer Feedback: An audible buzzer provides feedback during programming, memorization, and deletion processes, indicating successful operations or errors.
  • Multi-language Manual: The manual is provided in Italian, English, French, German, and Spanish, ensuring broad accessibility.

Maintenance Features

  • IP54 Protection: The IP54 rating indicates protection against dust ingress and splashing water, making it suitable for outdoor or semi-outdoor installations.
  • Thermoplastic ABS Casing: The robust ABS casing provides durability and protection for the internal components.
  • Cable Glands: The device is designed with cable glands to prevent water infiltration, requiring proper wiring to maintain its IP rating.
  • Self-diagnosis: The system includes features like automatic cycle interruption if working time is exceeded, which can help prevent motor damage and indicate potential issues.
  • Easy Access for Wiring: The design allows for straightforward wiring connections, with clearly marked terminals for power, sensors, and motor control.
  • Mounting Holes: Integrated fastening holes facilitate secure installation.

The device is designed to be installed by qualified personnel in compliance with relevant safety regulations. It is not suitable for direct UV exposure. Regular checks of the system's functionality, especially after programming or configuration changes, are recommended.