Inputs for rain, wind and
temperature (for ice) sensors.
Combination of rain and temperature
sensors to detect snow.
Self-learning procedure for limit switches and working times.
LED CARD (optional) to control the
1-colour, RGB or RGBW 24V
LED lights.
Independent or synchronized control of motor outputs.
Product code
M
24Vdc
/
M
24Vdc
M
24Vdc
M
24Vdc
M
24Vdc
24Vdc
M
230Vac
230
Vac
M
230Vac
M
230Vac
M
230Vac
230
Vac
24Vdc
24Vdc
M
230Vac
/
230
Vac
M
230Vac
M
230Vac
M
24Vdc
TVPLA868CC2(S) (h = 74mm) TVPLA868CC2B(S) (h = 50mm)
EN - 24V CONTROL UNIT WITH RADIO RECEIVER TO CONTROL ONE OR
TWO 24V MOTORS FOR ADJUSTABLE SLATS
TELECO AUTOMATION SRL
Via dell’Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com
This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
DOC.: T569.16_EN
TVPLA868CC2(S)-CC2B(S)
DATE: 06/04/18
Question and Answer IconNeed help?

Do you have a question about the Teleco TVPLA868CC2 and is the answer not in the manual?

Summary

Connections, Adjustments, and Control Unit Warnings

Motor Configuration

Pergola with 1 Motor

Configuration procedure for controlling a single 24V motor for adjustable slats.

Pergola with 2 Synchronized Motors

Configuration procedure for controlling two 24V motors synchronized for adjustable slats.

Pergola with 2 Independent Motors

Configuration procedure for controlling two 24V motors independently for adjustable slats.

Setting of Current Threshold During Configuration

Procedure to set the motor current threshold for stopping during configuration.

Transmitters

Radio Codes Memorization

Procedures for memorizing radio transmitter codes for control unit operation.

Radio Codes Deletion

Procedures for deleting single or all radio transmitter codes from the control unit.

Remote Memorization of Other Radio Codes

Procedure for remotely memorizing additional radio codes using a transmitter button.

Remote Deletion of a Radio Code

Procedure for remotely deleting a specific radio code using a transmitter button.

Sensors

WIND Sensor

Configuration and operation of the anemometer for wind speed detection.

SNOW Condition

Management of snow conditions based on temperature and rain sensor activation.

TEMPERATURE Sensor

Configuration and operation of the temperature sensor for ice formation detection.

RAIN Sensor

Configuration and operation of the rain sensor for water drop detection.

Change of Automatic Alarm Angles

Procedure to modify default pergola slat angles for alarm events.

Further Details

Troubleshooting (What to do IF...)

Guidance for diagnosing and resolving common problems with the control unit.

Replacing the Control Unit

Instructions for replacing a defective control unit while preserving configuration.

Quick Learning of Limit Switch

Procedure for self-learning limit switches without accessing the control unit.

Technical Specifications

Summary

Connections, Adjustments, and Control Unit Warnings

Motor Configuration

Pergola with 1 Motor

Configuration procedure for controlling a single 24V motor for adjustable slats.

Pergola with 2 Synchronized Motors

Configuration procedure for controlling two 24V motors synchronized for adjustable slats.

Pergola with 2 Independent Motors

Configuration procedure for controlling two 24V motors independently for adjustable slats.

Setting of Current Threshold During Configuration

Procedure to set the motor current threshold for stopping during configuration.

Transmitters

Radio Codes Memorization

Procedures for memorizing radio transmitter codes for control unit operation.

Radio Codes Deletion

Procedures for deleting single or all radio transmitter codes from the control unit.

Remote Memorization of Other Radio Codes

Procedure for remotely memorizing additional radio codes using a transmitter button.

Remote Deletion of a Radio Code

Procedure for remotely deleting a specific radio code using a transmitter button.

Sensors

WIND Sensor

Configuration and operation of the anemometer for wind speed detection.

SNOW Condition

Management of snow conditions based on temperature and rain sensor activation.

TEMPERATURE Sensor

Configuration and operation of the temperature sensor for ice formation detection.

RAIN Sensor

Configuration and operation of the rain sensor for water drop detection.

Change of Automatic Alarm Angles

Procedure to modify default pergola slat angles for alarm events.

Further Details

Troubleshooting (What to do IF...)

Guidance for diagnosing and resolving common problems with the control unit.

Replacing the Control Unit

Instructions for replacing a defective control unit while preserving configuration.

Quick Learning of Limit Switch

Procedure for self-learning limit switches without accessing the control unit.

Technical Specifications

Overview

The Teleco TVPLA868CC2(S) and TVPLA868CC2B(S) are 24V control units with integrated radio receivers designed to manage one or two 24V motors for adjustable slats, typically used in pergola systems. The TVPLA868CC2(S) has a height of 74mm, while the TVPLA868CC2B(S) has a height of 50mm.

Function Description

These control units enable the independent or synchronized control of motor outputs, allowing for flexible configuration of pergola slats. They feature a self-learning procedure for setting limit switches and working times, simplifying installation and calibration. The units are equipped with inputs for various environmental sensors, including rain, wind, and temperature (for ice detection), and can combine rain and temperature sensor data to detect snow conditions. An optional LED CARD (available only in the TVPLA868CC2(S) version) allows for controlling 1-colour, RGB, or RGBW 24V LED lights.

Important Technical Specifications

  • Power Supply: 24V
  • Max. Power for Each Output: 4.5A
  • Maximum Power Applicable to the Board: 240W (including the plug-in LED controller board)
  • Fuse (blade): 10A
  • Operating Temperature Range: -20°C to +45°C
  • Reception Frequency: 868.3 MHz
  • Radio Memory Capability (transmitters): 16
  • Rain Sensor Power Supply: 12 Vdc (max. 100mA)
  • Anemometer: 4 pulses/rotation (ANEM4)
  • Temperature Probe: NTC (R=10Kohm; B=3435K)
  • Protection Rating: IP54
  • Material of the Box and its Cover: Thermoplastic ABS (not suitable for direct UV exposure)

Usage Features

Motor Configuration: The control unit supports three motor configurations:

  1. Pergola with 1 motor: DIP4=OFF, DIP5=OFF. Press P1 and P2 simultaneously for 5 seconds to initiate configuration. The motor moves to its limit switches, and L1 flashes when reached. If the direction is wrong, invert motor wires.
  2. Pergola with 2 synchronized motors: DIP4=OFF, DIP5=ON. Press P1 and P2 simultaneously for 5 seconds. Both motors move together, and L1+L2 flash when limit switches are reached.
  3. Pergola with 2 independent motors: DIP4=OFF, DIP5=OFF for Motor 1; DIP4=ON, DIP5=OFF for Motor 2. Press P1 and P2 simultaneously for 5 seconds for each motor. Each motor is configured individually.

Self-Learning of Limit Switches: After motor configuration, press P1 and P2 simultaneously twice in quick succession, holding them for 5 seconds the second time. The system will cycle through complete closing and opening, learning the limit switch positions. L1 (or L1+L2 for synchronized motors, L2 for motor 2) will turn ON when the limit switch is reached. If movement doesn't stop, the current threshold may need adjustment.

Setting Current Threshold: The control unit uses a current threshold to stop motors. To adjust this:

  1. Turn the control unit OFF then ON.
  2. Within 10 seconds, set DIP6 to ON.
  3. Within 30 seconds, press P1 multiple times to select the desired current level (1=0.5A to 9=4.5A).
  4. Set DIP6 to OFF to store the value. L4 will flash to indicate the stored level. DIP6 must remain OFF during standard operation.

Transmitter Memorization: The system supports 7/42 channel, automatic (2 or 3 button), hold-to-run (2 or 3 button), and Green Mouse Screen transmitters. To memorize:

  1. Press P1 or P2 (depending on motor control mode) the required number of times for the transmitter type and hold the last time until a continuous sound is emitted.
  2. Press any button on the transmitter (or button 2 or 3 for Green Mouse Screen). An intermittent sound indicates successful memorization.

Radio Code Deletion:

  • Single Radio Code: Press P1 or P2 five times and hold the last time. An intermittent sound will be emitted. Press the button on the transmitter relative to the code to be deleted within 10 seconds. A continuous sound indicates successful deletion.
  • All Radio Codes: Press P1 or P2 six times and hold the sixth time for 10 seconds. A fast intermittent sound will be emitted. Release when the sound becomes continuous.

Remote Memorization/Deletion of Radio Codes:

  • Remote Memorization: Press and hold P3 on a memorized transmitter until a continuous sound is emitted. Press a button on an already memorized code, then press a button on the new code to be memorized.
  • Remote Deletion: Press and hold P3 on a memorized transmitter three times until a slow intermittent sound is emitted. Press a button on the code to be deleted within 5 seconds.

Sensor Management:

  • WIND Sensor (ANEM4): Detects wind speed. The control unit compares it to a threshold set by DIPs 1-2-3 (40-75 Km/h). If activated, pergola slats tilt to 33% of full opening, and no commands are executed.
  • SNOW Condition: Activated when temperature is below 2°C and rain is detected. Slats tilt to 66% of full opening, and only hold-to-run commands are executed.
  • TEMPERATURE Sensor (TMP150): Activates when temperature is below 2°C and slats are closed (danger of ice). Slats tilt to 10% of full opening.
  • RAIN Sensor (RAIN102): Detects water drops. If activated, pergola slats completely close, and no commands are executed. After the alarm ends, for 6 hours, slats tilt to 33% for water draining, and only hold-to-run commands are executed for 4 minutes.

Activation/Deactivation of Sensors:

  • TEMPERATURE Sensor: Press the "STOP" button of a memorized transmitter 10 times and hold the last time for 2 seconds. A continuous sound for 4 seconds activates it. Two beeps and L4 flashing every 3 seconds deactivates it.
  • RAIN Sensor: Press the "STOP" button of a memorized transmitter 10 times and hold the last time for 10 seconds. A continuous sound for 4 seconds activates it. Two beeps and L4 flashing every 2 seconds deactivates it. This can also be done via P2.

Change Automatic Alarm Angles: Press P1 or P2 the required number of times (8 for WIND, 9 for TEMP, 13 for SNOW, 10 for Reset) and hold the last time until a continuous sound is emitted. Put the slats to the desired angle.

Maintenance Features

Replacing the Control Unit: If the control unit is defective but the memory card is functional (board revision > 9.x), the unit can be replaced without losing configuration parameters.

  1. Ensure the control unit is not powered.
  2. Insert the memory card from the defective unit into the new one.
  3. Set the DIP switches on the new unit to match the old one.
  4. Switch the system on.

Quick Learning of Limit Switches: If motor control mode, correct motor direction, at least one transmitter per independent motor output, and current threshold are already programmed, self-learning of limit switches can be done without accessing the control unit.

  1. Test motor movement and direction using a memorized transmitter.
  2. Keep button P3 of the transmitter pressed for 10 seconds. The system will cycle through complete closing and opening, learning the limit switch positions.