12
P1
( 5 s)
continuous
sound
4 s
L4 ashes
once every 3 s
Activation/deactivation of the TEMPERATURE sensor by means of P1 *
ALARM ACTIVATED when What happens with ALARM ACTIVATED ALARM NOT ACTIVE when
The sensitive surface of the sensor detects
drops of water.
The control unit completely CLOSES the pergola slats. The
control unit executes no command.
The sensor doesn’t detect any drop.
System operation AFTER rain alarm (draining of water): once the rain alarm has ended, for the following 6 hours the control unit, upon receiving an
automatic movement command from the transmitter, will tilt the pergola slats to 33% to allow water to drain off. For 4 minutes the control unit can only execute
hold-to-run commands, thereby exiting from the alarm status.
RAIN sensor
1.1
4.4
Factory setting
ACTIVATED
Alarm priority
LOW
R
A
I
N
L4
ACTIVATION ***
(only if the sensor is connected)
DEACTIVATION ***
**
7x
Activation/deactivation of the RAIN sensor by means of the transmitter *
Deactivation
Press the “STOP” button of a memorized
7/42 or 3-channel transmitter for 10 s. The
buzzer emits 2 beeps. L4 ashes once
every 2 seconds.
Activation
Press the “STOP” button of a memorized
7/42 or 3-channel transmitter for 10 s.
The buzzer emits a continuous sound
for 4 seconds.
STOP
L4 ashes
once every 2 s
(10 s)
continuous
sound 4 s
STOP
(10 s)
Activation/deactivation of the RAIN sensor by means of P2 *
P2
( 5 s)
continuous
sound
4 s
L4 ashes
once every 2 s
ACTIVATION ***
DEACTIVATION ***
**
7x
* The motors must be stopped. ** The buzzer will make a beep each time the button is pressed. *** The motors make short movements
***
***