5
DIP4=OFF
DIP5=ON
Pergola with 2 synchronized motors
1. MOTOR CONFIGURATION
Together MOTOR 1 and MOTOR 2
2.2
...
Continuous sound
L3 ashes
Press P1 and P2 simultaneously
and hold for 5 s
...
P2
+
P1
( 5 s)
2. SELF-LEARNING OF LIMIT SWITCHES
ATTENTION:
ON
1 2 3 4 5 6
Press P1 and P2 simultaneously twice in quick succession and
hold them the second time for 5 s
DO NOT change the DIP conguration. This change would be signalled by a new intermittent sound and the ashing of L3,
and would require a new conguration procedure.
L1+L2
L1+L2
Closing
Opening
M
24Vdc
Check that movement
stops when the limit
switches are reached (L1
and L2 ON)
If it doesn’t, change the
threshold as per PAR 2.4
(page 7) and repeat.
LIMIT SWITCHES
CLOSE
OPEN
DIRECTION
P1 P2
If the direction is wrong, invert the motor wires.
= =
< 1 s
P2
+
P1
( 5 s)
P2
+
P1
complete
closing
complete
opening
complete
closing
complete
opening
...
...
...
...