Page #73 background image
Manual Door intercom devices a / b series 20 / 30 / 40 / 50 / 20-0028A/-0028B
Configurations and Set-up
GB
73www.behnke-online.com
Code Parameter Conrmation
00
Reset and restore default settings:
* * * * #
01
Change security code: Default setting: 0 0 0 0
new code [beep] new code #
02
Configuration and Set-up: Default setting: 0
0 = possible locally at the device and remotely
1 = only possible remotely
#
#
03
Answering a call: Default setting: 1
0 = manually by pressing a button
1 = automatically
2 = automatically with code request (call protection)
3 = automatically with manual confirmation (V1.60 or later)
#
#
#
#
04
Input delay for direct call buttons: Default setting: 0
0 = none
1 = 1 second
:
9 = 9 seconds
#
#
:
#
05
Connection interval: Default setting: 3
0 = unlimited (i.e. limited to approx. 8 hours)
1 = limited to 1 minute
:
9 = limited to 9 minutes
#
#
:
#
06 Volume: Default setting: 5
0 = soft
:
9 = loud
#
:
#