Manual Door intercom devices a / b series 20 / 30 / 40 / 50 / 20-0028A/-0028B
FAQ
GB
88 www.behnke-online.com
.

Door dials no or wrong telephone number
Telephone number from default settings has
not been re-configured
Wrong telephone number configured
Door intercom device has not accepted the
set-up, cf.: Door intercom device cannot be
configured
Remote station in the house rings once, no
voice call *2 (pause for 2 seconds) config-
ure before and after the telephone number
Door intercom device cannot be configured
remotely
The telephone with which you are configuring
the door intercom device does not send any
DTMF tones Use telephone with DTMF tone
Correctly enter the set-up mode with **0000
No (direct) voice call after connection
Check a / b port Port in the telephone
system must be generated as telephone port,
not as TFE/door intercom device/FTZ
Device is constantly initialising during set-up
Check a / b port, deactivate line monitoring if
activated, a / b port must not be disconnected
No busy tone after disconnection, but initialisa-
tion of the intercom
Check a / b port, there is no busy tone, but the
telephone system must send a busy tone after
the end of the call. Telephone system must
send a busy tone when ending the call.
Name plate not illuminated
Power supply is missing
Polarity of power supply is reversed
Check connection from name plate to basic
electronics
Door opener is not triggered
Check door opener connection Use closing
contact
Power supply for door opener missing
on-site (not parallel to Behnke power
supply)
Telephone does not send DTMF tones -> cf.:
Door intercom device cannot be configured
Code for opening doors is not or wrongly
configured (default setting 0#)
Confirm code entry with #
Door intercom device without function
Check a / b port, measure if necessary
If additional power supply is connected,
check if it is potential-free
Multiple door intercom devices are connected
in parallel each telephone requires its own
analogue connection and its own poten-
tial-free power supply
Coil current of the telephone system is
sufficient
must be more than 20 mA
Cf: Technical Specifications of the door inter-
com device

Other manuals for Telecom Behnke 10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telecom Behnke 10 Series and is the answer not in the manual?

Telecom Behnke 10 Series Specifications

General IconGeneral
BrandTelecom Behnke
Model10 Series
CategoryIntercom System
LanguageEnglish

Related product manuals