April 2018 Pathfinder DVL Guide
Page 68
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Table 14: Recommended Commands
Command Choices Description
CTx CT0 (default) or CT1 Setting the CT command to CT1 turns the Turnkey mode on. The Path-
finder will ping 10 seconds after power is turned on (see CT - Turnkey
Operation).
#EE0000010 Environmental data out-
put
Selects specialized Environmental data. Recommended to leave at the
default settings: default#EE0000010 (see EE - Environmental Data Out-
put).
EV00000 EV-17999 to EV18000
Sets the Heading Variation in degrees. Set EV = [(local magnetic declina-
tion)*100] (see EV - Heading Bias).
#PDx
PD0 (default), PD4, PD5,
PD6
Sets the output data format (see PD0 Output Data Format).
CK Keep parameters as user
defaults
If power is lost and then restored, all commands will be restored as last
sent (see CK - Keep Parameters). Sent right before the CS-command.
CS Start pinging Last command sent to begin collecting data (see CS Start Pinging (Go)).
The CR1 command must be the first command sent to the Pathfinder. The CK command must
be sent just before the CS command. Other commands may be sent in any order.