Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
70
8. Communication – 2. Voice Dialer – 4. VD Language
Setting the language for the voice dialer messages
The engineer can set the language of the voice messages transmitted from the voice dialer. Use the
digit buttons to set a two-digit value for different languages. The set value is confirmed with ENTER
button.
The available languages are as follows:
[00] - English
[01] - Portugese
[02] - Italian
Attention: Ask your distributer for more information whether the voice dialer supports your native
language and the value which corresponds to it.
Default setting: [00] - English
8. Communication – 2. Voice Dialer – 5. VD Phones – 1. Phone – 1. Phone Number
Setting of Telephone 1 for the voice dialer
The telephone number must not exceed 32 characters. Some special functions can be entered by
using the next button combinations:
1. Buttons / + 0 - Switches on "pulse dialer". “P” letter is displayed on the screen.
2. Buttons / + 1 - Switches on "tone dialer". “T” letter is displayed on the screen.
3. Buttons / + 2 - 2 seconds pause. “D” letter is displayed on the screen.
4. Buttons / + 3 - Switches on "Wait dial tone". “” symbol is displayed on the screen.
5. Buttons / + 4 - "Blind dialing"; Switches off "Wait dial tone". “#” symbol is displayed on the
screen.
6. Buttons / + 5 - Deletes the entered telephone number.
Note: The button is used in the previous design of the keyboards and has the same
functionality.
Default setting: none
8. Communication – 2. Voice Dialer – 5. VD Phones – 1. Phone – 2. Attach
Associating of areas to Telephone 1 for the voice dialer
According the system configuration the engineer associates one or several AREA numbers for
operation with Telephone 1. To select an AREA press the digit button corresponding to its number.
The next pressing of the same button will deselect the AREA.
To select all areas press button “0” – the button alternatively switches over all enabled / all disabled
state.
The Telephone 1 will be inactive if there are no associated areas to it!
Default setting: AREA 1
Telephone numbers from 2 to 8 for the voice dialer are programmed in an analogical way.