Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
81
62

Police panic alarm from keyboard
restored
KBD## Panic R
Keyboard No
3 12A
PR
63

Fire panic alarm sent from
keyboard
KBD## Fire
Keyboard No
1 11A
FA
64

Fire panic alarm from keyboard
restored
KBD## Fire R
Keyboard No
3 11A
FH
65

Keyboard blocking
KBD## Lockout
Keyboard No
1 421
JA
66

Entry in Engineer programming
menu
Installer In
-
1 627
LB
67

Exit from Engineer programming
menu
Installer Out
-
1 628
LX
68

Entry in Remote programming
mode
Download Start
-
1 411
RB
69

Exit from Remote programming
mode
Download End
-
1 412
RS
70

Periodical test
Periodic Tst Rep
-
1 6A2
TX
71

Manual test
Manual Tst Rep
-
1 6A1
TX
72

No AC mains power supply
AC Failure
-
1 3A1
AT
73

Mains power supply restore
AC Restore
-
3 3A1
AR
74

Battery low charge
Battery Low
-
1 3А2
YT
75

Battery loss
Battery Wlissing
-
1 311
YM
76

Battery restore
Battery Restore
-
3 3A9
YR
77

Siren output short-circuit
Bell Short
-
1 321
YA
78

Siren line broke out
Bell Absent
-
1 321
YA
79

Siren restored
Bell Restore
-
3 321
YH
80

2-wire fire line fault (PGM1)
Fire line Flt
-
1 373
FT
81

2-wire fire line fault restored
(PGM1)
Fire line Rstr
-
3 373
FJ
82

Fuse blown out
Fuse Blow
-
1 3AA
YP
83

Fuse restore
Fuse Restore
-
3 3AA
YQ
84

Telephone line loss
TLM trouble
-
1 351
LT
85

Telephone line restore
TLM restore
-
3 351
LR
86

System power up
Power UP
-
1 3A8
RR
87

System reset
Reset
-
1 3A5
YW
88

Time change
Time Changed
-
3 625
JT
89

Communication error for report to
monitoring station
Report Error
-
1 354
YC
90

Report to monitoring station restore
Report Restore
-
3 354
YK
91

Periphery device loss
D## Absent
Device No/ name
1 333
ET
92

Periphery device restore
D## Restore
Device No/ name
3 333
ER
93

Tamper form periphery device
D## Tamper
Device No/ name
1 145
TA
94

Tamper form periphery device
restore
D## Tamper R
Device No/ name
3 145
TR
95

Arming on no movement” failure
A## Failed AutoArm
Area No
-
-
96

User Code Changed
U## Code Changed
User No/ name
-
JV