EasyManua.ls Logo

Telit Wireless Solutions HE910 - Page 79

Telit Wireless Solutions HE910
111 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HE910 Hardware User Guide
1VV0300925 Rev. 32 Page 79 of 111 2019-11-25
The following table shows the typical input value of internal pull-up resistors for RTS DTR
and TXD input lines and in all module states:
STATE
RTS DTR TXD
Pull up tied to
ON
5K to 12K
1V8
OFF
Schottky diode
RESET
Schottky diode
POWER SAVING
5K to 12K
1V8
The input line ON_OFF and RESET state can be treated as in picture below
Figure 12-1 Input Line ON_OFF
NOTE:
According to V.24, some signal names are referred to the application
side, therefore on the HE910 side these signal are on the opposite
direction:
TXD on the application side will be connected to the receive line
(here named C103/TXD)
RXD on the application side will be connected to the transmit line
(here named C104/RXD)