Section 3 • Scheduled Maintenance ProceduresAugust 2016
Part No. 218567 AL4 • AL4000 3 - 25
C-1
Perform Engine Maintenance
Engine specifi cations require that this procedure
be performed every 500 hours.
Kubota D1105:
• Replace fan belt
• Flush coolant system
• Clean fuel tank
Perkins 403D-11:
• Clean radiator fi ns
• Inspect radiator coolant
• Inspect radiator hoses and clamps
• Change engine oil
• Replace oil fi lter
• Replace air fi lter
• Clean fuel tank
Required maintenance procedures and additional
engine information is available in the
Kubota D1105 Operator's Manual
(Kubota part number 16622-89166) OR the
Perkins 403D-11 User's Handbook
(Perkins part number SEBU8311-01).
Kubota D1105 Operator's Manual
Genie part number 131379
Perkins 403D-11 User's Handbook
Genie part number 131661
C-2
Clean the Light Assemblies
Terex specifi cations require that this procedure
be performed every 500 hours or semi-annually,
whichever comes fi rst.
Maintaining the light assemblies is essential to
good machine performance. Failure to regularly
clean the light assemblies may result in less light
than expected and, over time, could result in
damage to the machine.
Note: Perform this procedure with the light
assemblies out of direct sunlight and cool to the
touch.
1 Use clean, cool water to rinse the surface of
each light assembly.
2 Clean each light assembly using a soft cloth,
water and a mild dishwashing detergent.
Component damage hazard.
Harsh chemicals and cleaning
agents will damage the surface of
the light assembly. Do not allow
harsh cleaning agents to make
contact with the light surface.
3 Thoroughly rinse, then dry with a soft cloth.