August 2016
3 - 30 AL4 • AL4000 Part No. 218567
Section 3 • Scheduled Maintenance Procedures
D-1
Perform Engine Maintenance -
Kubota Models
Engine specifi cations require that this procedure
be performed every 1500 hours or bi-annually,
whichever comes fi rst.
• Injectors
Required maintenance procedures and additional
engine information is available in the
Kubota D1105 Operators Manual
(Kubota part number 16622-89166)
Kubota D1105 Operators Manual
Genie part number 131379
D-2
Perform Generator Maintenance
Leroy Somer Models
Generator specifi cations require that this
procedure be performed every 8000 hours or
annually, whichever comes fi rst.
Maintaining the generator in good condition is
essential to safe machine operation and long
service life. Storing the generator in a harsh
environment may require this procedure be
performed more frequently. Poor resistance may
result in a generator to lose effi ciency, and reduce
the life of the generator.
• Check resistance to ground on generator
windings, main rotating assembly, stator, exciter
fi eld and armature
Leroy Somer Manual
Genie part number 116118
Checklist D Procedures