August 2016
3 - 34 AL4 • AL4000 Part No. 218567
Section 3 • Scheduled Maintenance Procedures
E-5
Perform Generator Maintenance
Leroy Somer Models
Generator specifi cations require that this
procedure be performed every 20,000 hours or 3
years, whichever comes fi rst.
Maintaining the generator in good condition is
essential to safe machine operation and long
service life. Storing the generator in a harsh
environment may require this procedure be
performed more frequently. Allowing dirt and
grease to build up on the generator may result in a
generator which will run hotter, lose effi ciency, and
reduce the life of the generator.
Inspect and clean the generator end windings
for oil or dirt contamination
Leroy Somer Manual
Genie part number 116118
E-6
Perform Generator Maintenance
Leroy Somer Models
Generator specifi cations require that this
procedure be performed every 30,000 hours or 5
years, whichever comes fi rst.
Maintaining the generator in good condition is
essential to safe machine operation and long
service life. Storing the generator in a harsh
environment may require this procedure be
performed more frequently. Allowing dirt and
grease to build up on the generator may result in
a generator which will run hotter, lose effi ciency,
and reduce the life of the generator. Regular
replacement of the shaft bearing will extend the
service life of the generator.
Disassemble the generator, including rotor
removal
Inspect and clean generator components
including generator windings
Replace the generator shaft bearings. Consult
a trained Leroy Somer service professional.