49
Transmission overheating
Is the oil in the sump at the correct level ?
Is the oil cooler operating correctly ?
Do the oil pump pressure test as detailed in this
section. Is the oil pump serviceable ?
Do the torque converter relief valve pressure test
as detailed in this section. I s the torque con-
verter relief valve serviceable ?
Is the machine being operated correctly ?
Fillthesumpwiththeoilspecified
or remove excess oil from the sump.
T
roubleshooting procedure complete.
Remove and flush the oil cooler.
Replaceorrepairtheoilpump
Replace or repair the torque converter relie
f
valve
Replaceorrepairthetorqueconverter
Train the operator.
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
Do the circuit pressure test as detailed in this
section I. Is the circuit pressure correct ?
Contents