58.1
SERVICE
TRAINING
Cylinder Leak Down Rates
The Normal amount of Leak down in a 10 minute period with Hyd. Oil Temp at 140F.
Stabilizers 7/8 inch (20mm)
Extendable Dipper 1 ½ inches (40mm)
Backhoe Bucket 5/8 inch (15mm)
Dipper 5/8 inch (15mm)
Boom 5/8 inch (15mm)
Loader Beam 5/16 inch (8mm)
Cylinders will leak down because there are no Counterbalance Valves.