EasyManua.ls Logo

Terex Fermec 760 - Page 9

Terex Fermec 760
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cylinder Leak Down Rates
The Normal amount of Leak down in a 10 minute period with Hyd. Oil Temp at 140F.
Stabilizers 7/8 inch (20mm)
Extendable Dipper 1 ½ inches (40mm)
Backhoe Bucket 5/8 inch (15mm)
Dipper 5/8 inch (15mm)
Boom 5/8 inch (15mm)
Loader Beam 5/16 inch (8mm)
Cylinders will leak down because there are no Counterbalance Valves.
Leakage is at the Control Valves.
9
Service
Training
Contents