9011-22
95
REMOVAL AND INSTALLATION OF THE STABILIZER HYDRAULIC CYLINDER
(Centermount machines)
This information is applicable to a left-hand stabilizer
hydraulic cylinder. The procedure for a right-hand
stabilizer hydraulic cylinder is identical.
1. Park the machine on firm, level ground and lower
the stabilizer legs (2). Make sure the machine is
not raised from the ground.
2. Release the pressure from the hydraulic system
3. Place a suitable container below the hydraulic
lines and connections.
4. Disconnect the flexible hoses (3) and (4) from the
adaptors (5). Put caps on the flexible hoses (3)
and (4) and the adaptors (5).
5. Remove the circlips (6), the hook (7) and the
washer (8) from the upper pin (9).
6. Support the stabilizer hydraulic cylinder (1) at its
upper eye with suitable lifting equipment.
7. Use a soft metal drift to remove the upper pin (9).
8. If fitted, remove the bolts (11) and the rock guard
(10).
9. Remove the circlips (13) from the lower pin (12).
10. Use a soft metal drift to remove the lower pin
(12).
11. Remove the stabilizer hydraulic cylinder (1) from
the stabilizer leg (2).
12. Only carry out Step 13 if you install a
replacement stabilizer hydraulic cylinder (1) on
machine.
13. If fitted, remove the bolts (13), the nuts (14), the
clamp bracket (15) and the guide (16) from the
stabilizer hydraulic cylinder (1).
NOTE :
The installation of the stabilizer hydraulic
cylinder is in the reverse order from that of removal.
NOTE :
After installation, replenish the hydraulic
system.
NOTE :
After installation, carry out an operational test
of the stabilizer hydraulic cylinder (1). Make sure that
there are no leaks from the hydraulic lines and
connections that have been disturbed.