2. Specifications 9
2.8 Accuracy
Room temp.: 0.1% of span max
Temp. effects: 0.002%/°F of span max.
2.9 Response Time
Rise Time: 257ms. - 10 psi to 90 psi
F
all Time: 552ms. - 90 psi to 10 psi
Note: Step response into dead-end system (1 cubic inch volume).
2.10 Ports
Conduit: 1/2” NPT
Pneumatic: 1/8” NPT - Inlet, exhaust and gauge ports.
1/4” NPT - Controlled outlet port.
2.11 Weight
34.8 oz. (1.0 kg).
2.12 External Analog Input Impedance
4-20mA: 250
1
-5V: 220K - Single Input Pin to Gnd.
1.7M - Differential Input
0-10V: 100K
2.13 Digital Outputs
Current: 50 mA Continuous, 100 mA Instantaneous
Voltage: 5V - 28V
Type: Open collector, grounded emitter
2.14 Digital Inputs
Voltage Range/Input Impedance:
4-20 mA: 250
1-5V: 220K - Single Input Pin to Gnd.
1.7M - Differential Input
0-10V: 100K
Type: Level Sensitive
2.15 Analog Output
4-20mA: 0.5% Accuracy
2.16 Sensor Update Rate
25ms: Rate of sensor reading and processing task

Table of Contents