4. Installation 25
4.5.7 Networking ER3000’s
Up to 32 ER3000’s can be networked together, daisychained, as shown in Figure 16. The ER3000’s must be set up to different node
addresses before being networked together and powered-up. All ER3000’s are factory set to node address 250, therefore the address
must be changed to allow them to all communicate on the network. Changing the node address is accomplished by wiring an ER3000
as shown in Figure 2 and running the Windows ER3000 program. Once communicating to the ER3000 change the Node Number field
in the Miscellaneous Window from 250 to the desired node address. Repeat this process for all nodes.
Note: Power supply must be able to provide 300mA to each ER3000 in the network.
Figure 16: Networking/Daisychaining ER3000’s