Using the product 17
deenfresitptsvnl????
Ambient CO function:
- The time value is blinking.
1
Set measuring time (from 1 to 30 minutes) using / .
2
Start the measurement with the Start function key.
- The following values are displayed:
AmbCO: current ambient CO value in ppm.
aver.:average ambient CO value in ppm. Every minute the average
value is calculated. If the measured value is lower than the min value,
the min value will be set to the current value. If the measured value is
higher than the max value, the max value will be set to the current
value.
min: minimum ambient CO value in ppm.
max: maximum ambient CO value in ppm.
- Alarmlevels:
Current value > 10 ppm: The value blinks (1 sec on / 1 sec off).
Current value > 30 ppm: The value blinks (0.5 sec on / 0.5 sec off).
- After measuring time the average ambient CO value is displayed.
O
ption:
Stop the measurement with the Stop function key.
➣
Printing readings:
In order to be able to transfer data to a report printer via the infrared or
Bluetooth interface, the printer must be activated.
❯ (Settings → Printer → Select printer)
The printer 0554 0543 can only be selected when the Bluetooth
interface is activated.(Option testo 327-2)
❯ (Settings → Bluetooth → on/off)
The Print function key is only available if a printout is possible in the
instrument's current status.
❯ Start the printout with the Print function key.
- Printing out from Flue gas function: All readings taken since the
instrument was last switched on and transferred to the central Flue
gas measurement menu are printed out.
Printing out from other functions: Only those readings taken using the
respective measuring function are printed.