EasyManuals Logo

TESTO 435 Series User Manual

TESTO 435 Series
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
6.1.5 Language
²
Setting tthe llanguage:
The configuration menu is open, config. is displayed.
1 Language ¬ .
2 Select the desired language with / and confirm with .
6.2 Main menu
Settings by which the measuring instrument can be adapted to the particular
measuring task are performed in the main menu.
The instrument has predefined measurement profiles that are tailored to
specific areas of application.
º See the chapter PROFILE, p. 44.
The profile setting influences the number of available functions and the
structure of the main menu.
The method described in this chapter for calling up the functions in the main
menu relates to the Standard profile setting. If a different profile is set, the
method for calling up individual functions may change or the function may
not be available in that particular profile.
Menu overview testo 435-1/-3
Profile menu items Function
Standard P = 0 (nur 435-3) Zero internal pressure sensor
Area Set form, cross-section area, K-factor
Calc. Calculate volume flow, de/activate differential temperature;
435-3 additionally; De/activate flow calculation
Parameter Set reference pressure;
435-3 additionally; Set reference temperature/humidity.
cyc. Print De/activate cycle printing
Ductm. P = 0 (nur 435-3) Zero internal pressure sensor
Velocity (nur 435-3) De/activate flow calculation
Vol. De/activate volume flow calculation
Parameter (nur 435-3) Set reference pressure, Set reference temperature/humidity.
Pres. (nur 435-1) Set reference pressure
cyc. Print De/activate cycle printing
OK
OK
6. Setting the instrument 49
de
en
fresitptsvnl????

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 435 Series and is the answer not in the manual?

TESTO 435 Series Specifications

General IconGeneral
Temperature - NTC-20 to +70 °C
Temperature - Thermocouple Type K-50 to +1000 °C
Air Humidity0 to 100 %RH
CO20 to 10000 ppm
Dimensions220 x 74 x 46 mm
Measurement ParametersTemperature, Humidity, Air Velocity, Light Intensity, CO2
DisplayLCD
InterfaceUSB
Power SupplyBattery
Air Velocity - Thermal0 to +20 m/s
ResolutionVaries by parameter
AccuracyVaries by parameter
Battery Life20 h