4 Operation
14
4 Operation
4.1 Connecting
Always use refrigerant hoses that are specifically intended for
evacuations.
1 - Remove sealing caps.
- Connect the testo 552 to the circuit.
4.2 Switching instrument on and off
1
- Press .
The instrument switches on or off.
The instrument displays oooooo
when ambient pressure is applied to
the connections. The display
indicates the applied pressure value
once the applied pressure is within
the measuring range. (0 to 20,000
microns).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 552 and is the answer not in the manual?

TESTO 552 Specifications

General IconGeneral
TypeDigital Vacuum Gauge
Measurement Range0 to 26.66 mbar / 0 to 20000 microns
Battery Type2 x AA batteries
DisplayLCD
BluetoothYes
Protection ClassIP40
Storage Temperature-20 to +70 °C
Resolution1 micron (0 to 1000 microns)
Operating Temperature-10 to +50 °C
Accuracy±10 microns + 10% of m.v. (100 to 1000 microns)