6. Measuring 25
3
T
o reset:
Configuration mode is opened, RESET is lit.
iSelect the desired option with / and confirm
with :
· no: Instrument is not reset.
· Yes: Instrument is reset. The instrument is reset to
the factory settings.
- The instrument returns to measurement view.
6. Measuring
This chapter describes the steps that are required to
perform measurements with the product.
²
Setting the material characteristic curve:
1 Switch between the display of wood moisture (F) and
building moisture (M): or press .
2 Select the desired option with or and confirm
with :
Display Category Example
F 1 Softwood lumber Spruce, larch, cherry, pine, poplar, meranti
F 2 Hardwood lumber Beech, oak, maple, ash, Douglas-fir,
walnut, birch
F 3 Chipboard
M 1 Cement screed
M 2 Anhydrite screed
M 3 Concrete
M 4 Solid brick
M 5 High-insulating brick
M 6 Limestone
M7 Gas concrete
CAL Testing characteristic Not for on-site measurements!