EasyManuals Logo

Texas Instruments TAS5707 User Manual

Texas Instruments TAS5707
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
t
w(RESET)
RESET
t
d(I2C_ready)
SystemInitialization.
EnableviaI C.
2
T0421-01
I C Active
2
I C Active
2
f − Frequency − Hz
20
PVDD = 12 V
R
L
= 8
100 1k 10k
THD+N − Total Harmonic Distortion + Noise − %
20k
G002
P = 2.5 W
0.001
0.01
10
0.1
1
P = 0.5 W
TAS5707, TAS5707A
www.ti.com
SLOS556B NOVEMBER 2008REVISED NOVEMBER 2009
RESET TIMING (RESET)
Control signal parameters over recommended operating conditions (unless otherwise noted). Please refer to Recommended
Use Model section on usage of all terminals.
PARAMETER MIN TYP MAX UNIT
t
w(RESET)
Pulse duration, RESET active 100 us
t
d(I2C_ready)
Time to enable I
2
C 13.5 ms
NOTE: On power up, it is recommended that the TAS5707 RESET be held LOW for at least 100 μs after DVDD has reached
3.0 V
NOTE: If the RESET is asserted LOW while PDN is LOW, then the RESET must continue to be held LOW for at least 100 μs
after PDN is deasserted (HIGH).
Figure 5. Reset Timing
TYPICAL CHARACTERISTICS, BTL CONFIGURATION
TOTAL HARMONIC DISTORTION + NOISE TOTAL HARMONIC DISTORTION + NOISE
vs vs
FREQUENCY FREQUENCY
Figure 6. Figure 7.
Copyright © 2008–2009, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Link(s): TAS5707 TAS5707A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TAS5707 and is the answer not in the manual?

Texas Instruments TAS5707 Specifications

General IconGeneral
BrandTexas Instruments
ModelTAS5707
CategoryAmplifier
LanguageEnglish

Related product manuals