TAS5707, TAS5707A
SLOS556B –NOVEMBER 2008–REVISED NOVEMBER 2009
www.ti.com
RECOMMENDED OPERATING CONDITIONS (continued)
MIN NOM MAX UNIT
T
J
(1)
Operating junction temperature range 0 125 °C
R
L
(BTL) Load impedance Output filter: L = 15 μH, C = 680 nF. 6 8 Ω
Minimum output inductance under 10
L
O
(BTL) Output-filter inductance μH
short-circuit condition
(1) Continuous operation above the recommended junction temperature may result in reduced reliability and/or lifetime of the device.
PWM OPERATION AT RECOMMENDED OPERATING CONDITIONS
PARAMETER TEST CONDITIONS VALUE UNIT
11.025/22.05/44.1-kHz data rate ±2% 352.8 kHz
Output sample rate
48/24/12/8/16/32-kHz data rate ±2% 384
8 Submit Documentation Feedback Copyright © 2008–2009, Texas Instruments Incorporated
Product Folder Link(s): TAS5707 TAS5707A