EasyManuals Logo

Texas Instruments TMS320F2837 D Series Errata Sheet

Texas Instruments TMS320F2837 D Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
www.ti.com
Usage Notes and Known Design Exceptions to Functional Specifications
17
SPRZ412KDecember 2013Revised February 2020
Submit Documentation Feedback
Copyright © 2013–2020, Texas Instruments Incorporated
TMS320F2837xD Dual-Core MCUs Silicon Revisions C, B, A, 0
Advisory Flash: A Single-Bit ECC Error May Cause Endless Calls to Single-Bit-Error ISR
Revision(s) Affected 0, A, B, C
Details When a single-bit ECC error is detected, the CPU executes the single-bit-error interrupt
service routine (ISR). When the ISR returns, the same instruction that caused the first
error is fetched again. If the ECC error threshold (ERR_THRESHOLD.THRESHOLD)
is 0, then the same error is detected and another ISR is executed. This continues in an
endless loop. This sequence of events only occurs if the error is caused by a program
fetch operation, not a data read.
Workaround(s) Set the error threshold bit-field (ERR_THRESHOLD.THRESHOLD) to a value greater
than or equal to 1. Note that the default value of the threshold bit-field is 0.
Advisory Flash: Minimum Programming Word Size
Revision(s) Affected 0, A, B, C
Details The Main Array flash programming must be aligned to 64-bit address boundaries and
each 64-bit word may only be programmed once per write/erase cycle.
Applications using Fapi_issueProgrammingCommand() in Fapi_AutoEccGeneration or
Fapi_DataAndEcc modes are implicitly performing 64-bit programming since ECC is
programmed for each 64 bits. Applications using Fapi_DataOnly mode with fewer than
64 bits may be impacted by this advisory.
The DCSM OTP programming must be aligned to 128-bit address boundaries and each
128-bit word may only be programmed once. The exceptions are:
1. The DCSM Zx-LINKPOINTER1 and Zx-LINKPOINTER2 values in the DCSM OTP
should be programmed together, and may be programmed 1 bit at a time as required
by the DCSM operation.
2. The DCSM Zx-LINKPOINTER3 value in the DCSM OTP may be programmed 1 bit at
a time as required by the DCSM operation.
Workaround(s) All applications should follow the restrictions outlined in this advisory. Contact TI for
devices already in production which violate this advisory.

Other manuals for Texas Instruments TMS320F2837 D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TMS320F2837 D Series and is the answer not in the manual?

Texas Instruments TMS320F2837 D Series Specifications

General IconGeneral
BrandTexas Instruments
ModelTMS320F2837 D Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals