Premier 412/816/832 Quick Guide
INS184-8 3
Partition Programming
Menus: -
Partition Timers Menu: Partition Options
Exit Time
Entry Delay 1
Entry Delay 2
Comms Delay
Bell Delay
Bell Duration
1: Enable Auto Bypass Mode
2: Stay Armed Exit is Silent
3: Enable Remote Arming
4: Enable Remote Disarming
5: Enable Local Exit Tones
6: Stay Armed Entry is Instant
7: Stay Armed Exit is Delayed
8: Only Start Exit when Partition is
Ready
Menu:
Partition Auto Arm/Disarm Menu: Equipment Areas
1: Auto Arm with Control Timer 1
2: Auto Arm with Control Timer 2
3: Auto Arm with Control Timer 3
4: Auto Arm with Control Timer 4
5: Auto Disarm with Control Timer 1
6: Auto Disarm with Control Timer 2
7: Auto Disarm with Control Timer 3
8: Auto Disarm with Control Timer 4
Partition 1 Partition 2 Partition 3 Partition 4
0: Auxiliary Input Areas
1: Panel Bell Areas
2: Bell Squawk Areas
3: Anti-Masking when Armed
Global Programming
Menu:
Global System Timers Menu: Global Counter/Levels
00: AC Fail Delay
01: Line Fault Delay
02: Cross Zone Time
03: Zone Soak Test Time
04: Restore Reporting Delay
05: Output Short Pulse Time
06: Zone Response Time
07: Transmission Abort
08: Test Transmission Time
09: Courtesy Delay
10: Service Timer
11: 2-Wire Verified Delay
12: Alarm Confirmation
Delay
13: Activity Time Window
14: Poll IP Every
0: Swinger Shutdown Count
1: Panel Speaker Volume
2: Chime Volume)
3: Clock Adjustment
4: Language
5: Country Code
Timer 1: On/Off Time
Timer 2: On/Off Time
Timer 3: On/Off Time
Timer 4: On/Off Time
Days of Operation
On Time: Su Mo Tu We Th Fr Sa
Off Time: Su Mo Tu We Th Fr Sa
Menu: System Options 1 Menu: System Options 2
1: Clock = Crystal
2: Battery Connection Supervision
3: Battery Dynamically Load Tested
4: Panel NVM is Locked
5: Power Savings During AC Mains Failure
6: Line Fault Overrides Bell Delay
7: 2-Wire Smoke Detection on O/P 1
8: Convert Siren Output from Voltage to Speaker Driver
1: Tamper Alarms Cause a Trouble While Disarmed
2: Tamper Alarms Cause a Trouble While Stay Armed
3: Defer Reporting of Non-Zone Restorals
4: Use Delay Timer to Defer Non-Zone Restorals
5: Inhibit Keyswitch Operation on EOL Tamper
6: Away Arm Overrides Alarm Tx Delay
7: Defer Reporting of Zone Restorals
8: Use Delay Timer to Defer Zone Restorals
Menu: System Options 3 Menu: Hardware Options
1: Away Arm Exit Error Doesn’t Sound Bell
2: Zone Test - Silence on No Violation
3: Alarm Status Light Indicates Fire
4: Enable Entry/Exit Tones for Panel Speaker
5: Enable Cross Partitioning
6: Enable EN 50131-1 Requirements
7: Reinstate Bypassed Zones on Disarm
8: Invert Panel Siren Output
1: Panel Output 1 Supervised for Faults
2: Panel Output 2 Supervised for Faults
3: Siren/Bell O/P Supervised for Faults
4: Panel Box Tamper Switch Monitored
5: Auxiliary Fuse Supervised for Faults
6: Battery Supervised for Faults
7: AC Mains Supply is Monitored
8: Telephone Line Is Monitored
Menu: Auxiliary Input
0: Not Used
1: Auxiliary Tamper
2: Remote Reset
3: Line Fault
4: Panic Alarm
5: Silent PA
6: Latched Keyswitch
7: Momentary Keyswitch