Premier Elite 8XP Installation Manual
6 INS179-5
2. Specifications
Operating Voltage: 10 -14VDC
Network
4-wire standard 7/0.2 alarm cable up to 250m.
Star, Daisy Chain or any combination.
Zones: 8 fully programmable
Outputs 1- 8: 100mA switched -ve
Minimum impedance 8Ω
Operating Temperature:
-10°C (+14°F) to +50°C (+122°F)
Storage Temperature:
-20°C (-4°F) to +60°C (+140°F)
Maximum Humidity: 95% non-condensing
Dimensions: 170mm x 140mm x 35mm
Material: 3mm ABS
Packed Weight: 200g
EMC Environment Residential, Commercial, Light Industrial or
Industrial
Standards
2004/108/EC (CE directive): Hereby, Texecom declares that this device is
in compliance with the essential requirements and other relevant provisions
of Directive 2004/108/EC.
Weee Directive: 2002/96/EC (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this product to your local
supplier upon the purchase of equivalent new equipment, or dispose of it
at designated collection points. For more information see:
www.recyclethis.info.
RoHs Directive: 2002/95/EC RoHS Compliant. Hereby, Texecom declares that this device
does not contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls
(PBB) or polybrominated depheny ethers (PBDE) in more than the percentage specified by
EU directive 2002/95/EC, except exemptions stated in EU directive 2002/95/EC annex.
This product is a Type B Moveable device and is suitable for use in systems designed to
comply with EN 50131-1, EN50131-3 and PD6662 at Grade 3 and Environmental Class II.
Warranty
All Texecom products are designed for reliable, trouble free operation. Quality is carefully monitored by extensive
computerised testing. As a result the Premier 8XP is covered by a two-year warranty against defects in materials or
workmanship.
As the Premier Elite 8XP is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or
liability for any damages whatsoever based on a claim that the control panel failed to function correctly.
Due to our policy of continuous improvements Texecom reserve the right to change specification without prior notice.