BHT-206A/B-SERIES-MM-1
5-00-00
30 APR 2013 Rev. 14 Page 121
Export Classification C, ECCN EAR99
SCHEDULED INSPECTIONS
5-37. 600 HOURS OF COMPONENT OPERATION
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. _____________________
FACILITY: __________________________________________
HELICOPTER S/N: ___________________________________
REGISTRY NO.: _____________________________________
TOTAL TIME:_______________________________________
SIGNATURE:________________________________________
NOTE
If all five of the following modifications have been
carried out on transmission 206-040-002-005, this
600-hour inspection is not required. Refer to the
1200 hours of component operation scheduled
inspection (paragraph 5-39).
NOTE
Transmissions delivered, which were marked CHG
instead of MOD on data plate, are to be considered
as having modification completed.
MOD 1: First line of data plate. Transmission sun gear
206-040-123-003 with shaft 206-040-040-003. (refer to
SL 206A-30).
MOD 2: Second line of data plate. Pinion 206-040-035-007
(refer to SL 206A-112).
MOD 3: Third line of data plate. Installation of top case
206-040-151-009.
MOD 4: Fourth line of data plate. Heavy duty spider
206-040-080-003 with three longer shafts 206-040-043-005
(refer to SB 206A-14).

Table of Contents