8.4 Checking sacrificial anode
Unscrew the sacrificial anode
1
.
Information! The water jacket in the exhaust manifold is protected from corrosion by a passive
cathodic protection.
Check the sacrificial anode
2
.
At least half of the original size 60 mm
[2.4 in], Ø 16 mm [0.6 in] remains.
If the sacrificial anode is less than half of the
original size, replace the sacrificial anode.
Replace the seal
4
.
Screw in the sacrificial anode
3
.
Tightening torque:
41 Nm +9 Nm [30.2 lbf ft +6.6 lbf ft]
Touch up paintwork defects.
8 Service tasks in the workshop
8.4 Checking sacrificial anode