5.10.2.2 PLATFORM INSTALLATION ELECTRICAL WIRING (-P MODELS)
The electronics enclosure converts discrete input signals into serial communications for controlling the monitor. The discrete input
signals can be from a joystick, toggle switches, relay contacts or Canbus output module. The electronic interface accepts +12/24 VDC
signals, but can be field changed to accept ground signals.
The electronics enclosure is configured so that signals connected to the PRIMARY CONTROL cable will override any other operator
stations (see section 6.2.1).
See Figure 5.10.2.2 for wiring connections.
Figure 5.10.2.2
Electrical Components
(platform installations)
NOTE: To avoid excessive voltage drop at monitor
operator station, cable selection is critical.
Voltage supplied to ELECTRONICS ENCLOSURE should
not fall below 11 volts when monitor is in operation.
Recommended
Cable Gauge
Max Length Gauge
40ft....14AWG
65ft....12AWG
80 ft . . . 2-14AWG
105 ft . . . 10AWG
130 ft . . 2-12AWG
(Y4E-TS)
(NOT INCLUDED)
OPTIONAL TOGGLE SWITCH
OPERATOR STATION
SECTION 5.5
FROM CANBUS OUTPUT MODULE
MONITOR MOUNTED
OPERATOR STATION

Table of Contents

Other manuals for TFT Tornado RC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TFT Tornado RC and is the answer not in the manual?

TFT Tornado RC Specifications

General IconGeneral
BrandTFT
ModelTornado RC
CategoryFirefighting Equipment
LanguageEnglish

Related product manuals