©Copyright Task Force Tips, Inc. 2004-2018 LIX-530 December 31, 2018 Rev14
rc3 & RC4
TM
Telescoping Waterway for Deck Mounted Monitors
For use with Serial #’s above X505163
INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE
DANGER
Read instruction manual before use. Operation of this device without understanding the manual
and receiving proper training is a misuse of this equipment. A person who has not read and
understood all operating and safety instructions, is not qualifi ed to operate the Extend-A-Gun
RC3 or RC4 telescoping unit.
TASK FORCE TIPS LLC
MADE IN USA • TFT.com
3701 Innovation Way, Valparaiso, IN 46383-9327 USA
800-348-2686 • 219-462-6161 • Fax 219-464-7155
CONTROL BOX
(complete with 10 ft (3m) of power & communication cable
for connection to monitor communication link & power,
12 ft (3m) of cable for connection to RC monitor,
and 12 ft (3.6m) of cable for connection to RC Extend-A-Gun motor)
Shown with
Monsoon RC Monitor
and Master 2000 Nozzle.
(Monitor, Nozzle and
Mounting Brackets not included)
OPTIONAL PUSHBUTTON STATION
(complete with 12 ft (3.6m) cable
for connection to control box)
LOWERED
POSITION
RAISED
POSITION

Questions and Answers

  • K
    kingchristopherAug 11, 2025
    What to do if my TFT Firefighting Equipment does not raise?
    • T
      Theresa HawkinsAug 11, 2025
      If your TFT Firefighting Equipment does not raise, the issue might stem from low voltage due to factors like an inadequate apparatus electrical system, wire gauge being too small, wire length being too long, or poor connections. Mechanical binding or damage to the chain drive could also be the cause. First, check the connections and wiring. Ensure the voltage is above 8 volts. Then, use the manual override to check the mechanical operation. If problems persist, further consultation may be required.
  • R
    Rebecca BaldwinAug 21, 2025
    What to do if my TFT Extend-A-Gun RC3 Firefighting Equipment does not lower?
    • E
      ernest84Aug 22, 2025
      If your TFT Firefighting Equipment does not lower, it could be due to several reasons: low voltage (caused by a wire gauge that's too small, a wire length that's too long, a poor connection, or an inadequate apparatus electrical system), mechanical binding, the monitor not being in PARK position, or damage to the chain drive. Check the connections and wiring. Verify the voltage is above 8 volts. Use the manual override to verify mechanical operation. Perform the Monitor PARK operation. If the issue persists, further consultation may be required.
  • T
    Trevor BlevinsAug 31, 2025
    How to fix leaks in TFT Extend-A-Gun RC3?
    • S
      Steven JohnsonAug 31, 2025
      Leaks in TFT Firefighting Equipment are often caused by debris or damage in the seal area. To address this, clean out any debris present. If the parts are damaged, replace them.

TFT Extend-A-Gun RC3 Specifications