Appendix
RAMSES 718 P / RAMSES 718 S 88
6.3 Operating mode as scene (RTC)
6.3.1 Principle
The current operating mode can be saved via an object with the scene functions and restored
later at any time.
The current operating mode is allocated to the appropriate scene number when a scene is
saved.
The previously saved operating mode is reactivated when a scene number is called.
This allows the device to be easily associated to each chosen user scene.
The scenes are permanently stored and remain intact even after the application has been
downloaded again.
In order to save or call up the scene, the respective code is sent to the object Operating mode as
seen.
Scene
Call up
Save
Scene
Call up
Save
Hex
Dec.
Hex
Dec.
Hex
Dec.
Hex
Dec.
1
$00
0
$80
128
33
$20
32
$A0
160
2
$01
1
$81
129
34
$21
33
$A1
161
3 $02 2 $82 130 35 $22 34 $A2 162
4
$03
3
$83
131
36
$23
35
$A3
163
5
$04
4
$84
132
37
$24
36
$A4
164
6
$05
5
$85
133
38
$25
37
$A5
165
7
$06
6
$86
134
39
$26
38
$A6
166
8
$07
7
$87
135
40
$27
39
$A7
167
9
$08
8
$88
136
41
$28
40
$A8
168
10 $09 9 $89 137 42 $29 41 $A9 169
11
$0A
10
$8A
138
43
$2A
42
$AA
170
12
$0B
11
$8B
139
44
$2B
43
$AB
171
13
$0C
12
$8C
140
45
$2C
44
$AC
172
14
$0D
13
$8D
141
46
$2D
45
$AD
173
15
$0E
14
$8E
142
47
$2E
46
$AE
174
16
$0F
15
$8F
143
48
$2F
47
$AF
175
17
$10
16
$90
144
49
$30
48
$B0
176
18
$11
17
$91
145
50
$31
49
$B1
177
19
$12
18
$92
146
51
$32
50
$B2
178
20
$13
19
$93
147
52
$33
51
$B3
179
21
$14
20
$94
148
53
$34
52
$B4
180
22
$15
21
$95
149
54
$35
53
$B5
181
23 $16 22 $96 150 55 $36 54 $B6 182
24
$17
23
$97
151
56
$37
55
$B7
183
25
$18
24
$98
152
57
$38
56
$B8
184
26
$19
25
$99
153
58
$39
57
$B9
185
27
$1A
26
$9A
154
59
$3A
58
$BA
186
28
$1B
27
$9B
155
60
$3B
59
$BB
187
29
$1C
28
$9C
156
61
$3C
60
$BC
188
30 $1D 29 $9D 157 62 $3D 61 $BD 189
31
$1E
30
$9E
158
63
$3E
62
$BE
190
32
$1F
31
$9F
159
64
$3F
63
$BF
191

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Theben KNX Series and is the answer not in the manual?

Theben KNX Series Specifications

General IconGeneral
Communication ProtocolKNX
Ambient Temperature-5°C to +45°C
Storage Temperature-25°C to +70°C
Protection ClassIP20
Relative Humidity5% to 95%, non-condensing
Operating Voltage24 V DC (via KNX bus)