Expanding a RAID
To expand a RAID 1, RAID 5, RAID 6, or RAID 10 volume, follow the steps below:
1. Replace one of the hard drives in the RAID volume and allow it to
automatically rebuild.
2. Once rebuilt, you can continue to replace any remaining disks in the RAID
array.
3. When you are done replacing hard drives, log on to Web Management.
Navigate to Storage > RAID to open the RAID List screen.
4. On the RAID List screen, select the RAID volume by clicking on its radio
button, and click RAID Config to open the RAID Configuration screen.
5. On the RAID Configuration screen, click Expand.
Migrating a RAID
Once a RAID volume has been created, you
may want to move it to other physical drives
or change the RAID array all together. To
migrate a RAID 0, RAID 1, or RAID 5
volume, follow the steps
below:
1. From the RAID Configuration screen,
click Migrate RAID.
2. A list of possible RAID migration
configurations will be listed. Select
the desired migration scheme and
click OK.
3. The system will begin migrating the RAID volume.
NOTE
From
RAID 0 RAID 5
RAID 0
[RAID 0] HDDx2 to [RAID 0] HDDx3
[RAID 0] HDDx2 to [RAID 0] HDDx4
[RAID 0] HDDx2 to [RAID 0] HDDx5
[RAID 0] HDDx3 to [RAID 0] HDDx4
[RAID 0] HDDx3 to [RAID 0] HDDx5
[RAID 0] HDDx4 to [RAID 0] HDDx5
[RAID 0] HDDx2 to [RAID 5] HDDx3
[RAID 0] HDDx2 to [RAID 5] HDDx4
[RAID 0] HDDx2 to [RAID 5] HDDx5
[RAID 0] HDDx3 to [RAID 5] HDDx4
[RAID 0] HDDx3 to [RAID 5] HDDx5
[RAID 0] HDDx4 to [RAID 5] HDDx5
RAID 1
[RAID 1] HDDx2 to [RAID 0] HDDx2
[RAID 1] HDDx2 to [RAID 0] HDDx3
[RAID 1] HDDx2 to [RAID 0] HDDx4
[RAID 1] HDDx2 to [RAID 0] HDDx5
[RAID 1] HDDx2 to [RAID 5] HDDx3
[RAID 1] HDDx2 to [RAID 5] HDDx4
[RAID 1] HDDx2 to [RAID 5] HDDx5
32