To be able to chose a specific function, the sensor for that function must be connected.
▪
HOT WATER
▪
HEATING
▪
COOLING
▪
AUX. HEATER
▪
MANUAL TEST
▪
INSTALLATION
▪
SYSTEM
▪
HEAT SOURCE
▪
POOL
▪
DISTRIBUTION CIRCUIT 1-2
▪
BUFFER TANK
▪
OPTIMUM
▪
CURRENT LIMITER
▪
START UP CHECK
▪
SERVICE TIME
▪
FACTORY SET
▪
RESET OPER. TIME
▪
SENSOR CALIBRATION
▪
VERSION
▪
LOG TIME
▪
DEFROST
▪
OPTIMUM
▪
BUFFER TANK
8.2
HOT WATER
Parameter Meaning
START Start temperature for hot water production. Shows the actual weighted hot water temperature and the value
within brackets indicates the start temperature. ( = no hot water production)
Factory setting: 40°C, range: , 30°C – 55°C
HOT WATER TIME Time for hot water production during combined hot water demand and heating or cooling demand, in minutes.
Factory setting: 20M, range: 5M – 40M
TOPH. INTERVAL Time interval between peak heating chargings (anti-legionella function) in days. Operating mode that permits
auxiliary heater must be selected.
Factory setting: 7D, (range: , 1D – 90D
TOPH. TIME Time in hours that the legionella demand is to be fulfilled for peak heating charging to be considered com-
plete.
Factory setting: , range: , 1H – 10H
TOPH. STOP Stop temperature for peak heat charging. Operating mode that permits auxiliary heater must be selected.
Factory setting: 60°C, range: 50°C – 65°C
INFL. H.W SENSOR. Hot water sensor’s influence compared with the peak sensor’s at start of water heating.
Factory setting: 65%, range: 0% – 100%