48
TK 61651-18-OP-EN
V-800 and Spectrum
Fuse 6: Drain Heaters 1/2 2 amps 2 amps
Fuse 8: (Spectrum Only) EVAP2 Liquid Solenoid
Valve (PS2), EVAP1 Liquid Solenoid Valve (PS3),
EVAP2 Defrost Hot Gas Solenoid Valve (PS4), Drain
Heaters 3 and 4 (HT3, HT4)
20 amps 10 amps
Fuse 9: (Spectrum Only) Evaporator Fan 3 15 amps 10 amps
Fuse 10: (Spectrum Only) Evaporator Fan 4 15 amps 10 amps*
Fuse 11: Drain Heaters (H3 and H4) 2 amps 2 amps
Fuse 15: TracKing 5 amps 5 amps
Fuse 16: TracKing 5 amps 5 amps
Fuse 17: TracKing 5 amps 5 amps
Fuse 20: Transformer AC Power Supply (located at
compressor motor contactor in condenser section)
2 x 2 amps 2 x 2 amps
Fuse 21: Battery Power Supply (located in 2 wire
near battery)
2 x 30 amps 2 x 30 amps
Fuse 31: Condenser Fan Motor 2 (CFM2) (located in
CF2 wire near terminal strip in condenser section)
16 amps 10 amps
Note: * 15 A in Spectrum Versions with Double Evaporator Fan 4
Condenser Fan Motor (All except V-800)
Voltage 13 Vdc 26 Vdc
Full Load Current 10 Amps 4.7 Amps
Power Rating 130 W 122 W
RPM with Full Load 2,800 2,800
Condenser Fan Motor (V-800)
Voltage 13 Vdc 26 Vdc
Full Load Current 11 Amps 9 Amps
Power Rating 145 W 230 W
RPM with Full Load
2,670 2,900
SSppeecciiffiiccaattiioonnss