4.12 Display messages
4 Operation, maintenance and cleaning
Error No. + Picture Text Cause Clearing
TX0001 Ready Machine is ready -
TX0101
NTC coffeeboiler open Problem with tempe-
rature check in coffee
boiler
Call service
TX0104
Empty grounds drawer Grounds drawer is full Remove and empty
grounds drawer, than
reinsert
TX0106
Grounds drawer missing Grounds drawer is not
correctly inserted
Insert grounds drawer
again
TX0107
Bean hopper empty (left-
hand side)
The left bean hopper is
empty
Rellcoffeebeansonthe
left bean hopper
TX0108
Service required Amount of programmed
brew cycles is reached
Call service
TX0109
Clean appliance Amount of programmed
brew cycles or hours to
clean the machine is
reached
Clean the machine
TX0110
Voltage low Voltage is too low 1. Wait for the voltage to
normalize
2. Call service
TX0111
Voltage high Voltage is too high 1. Wait for the voltage to
normalize
2. Call service