Loading...
REV-4
3.29
SECTION 3
© 2009 by Thermoplan AG, Subject to change
Technical Manual
General Programming Hints
23
1
56
4
89
7
Enter PIN
****
Touch the upper left corner on the Touchscreen. The access window for the
Service-Code appears.
Service-Code for programming level: 1111
NAVIGATION
Press the „step“ key to enter the programming menus.
Step
Step forward
Press „step“-key.
Step
Step backwards
Press „back“-key.
Back
Settings
Set parameters with the „Plus“ or „Minus“ key.
+ -
Save settings
Press „step“ key.
Step
PRODUCTPARAMETER
To set the several productparameter select rstly the product and then set with
the „Plus“ or „Minus“ key.
Product Plus-/Minus
TEST-COFFEE
It is necessary to test the values, changed in the programming mode, imme-
diately. By pressing the corresponding product key for 2sec., a test coffee
can be supplied without leaving the programming mode.
Function is only available in the menu:
Powder quantity, prebrew time, relax time and press after
For the test coffee, the waiter-, cash- and coin-systems are not active.
DOUBLE-PRODUCT KEYS
All models have 8 or 12 product keys.
With the „Double“ key two or more cups of the desried beverage can be
produced.
Double product: „X“ Double product in one brew cycle
Multiple product: „2“ - „9“ Multiple products with one brew cycle
for each product
2x
Important hint
Double products can also be programmed individually on one single button.
Please note that double-product settings or changes in the menus
- Water quantity
- Coffee aroma
- Powder quantity
- Bypass
are made in the program „1 cup“.