Rev K Jan 2020
Page 42
Chapter 7 Software Reference
7.3.3 Advanced Tab
Fig. 7.7 Advanced Settings
Button Control Settings
The buttons on the front of the unit can be used either to jog the motor, or to perform
moves to absolute positions.
Button Mode: This setting determines the type of move performed when the front
panel buttons are pressed.
Jogging: Once set to this mode, the move parameters for the buttons are taken
from the ‘Jog’ parameters on the ‘Move/Jogs’ settings tab.
Go to Position: In this mode, each button can be programmed with a different
position value, such that the controller will move the motor to that position when
the specific button is pressed.
Note. The following parameters are applicable only if Go to Position is selected in the
Button Modefield.
Left/Top Button Pos.: The position to which the motor will move when the top
button is pressed.
Right/Bottom Button Pos.: The position to which the motor will move when the
bottom button is pressed.
Note. A ‘Home’ move can be performed by pressing and holding both buttons for 2
seconds. This function is irrespective of the ‘Button Mode’ setting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS LTS Series and is the answer not in the manual?

THORLABS LTS Series Specifications

General IconGeneral
BrandTHORLABS
ModelLTS Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals