30
4
5
Hit the "5" button. Nozzle will go
to the center of the platform.
Raise the platform until it is
just touching the nozzle. Move
the paper between the nozzle
and platform and see if there
is any resistance.
Platform too high, nozzle
is pinning paper onto
the platform, Lower the
platfrom slightly.
Just right, could feel
some resistance
when moving the
paper.
Platform too low, no
resistance at all when
moving paper, raise
the platform slightly.
When obtained the right platform
height, write down the value of "current
height".
We will refer this as the
"platform
height value".
Repeat step 1- 6 for all other 8
positions and obtain their platform
height values.