1. General Information
These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
Before installation or maintenance, ensure the mains supply to the
Programmer is switched off and the circuit supply fuses are removed
or the circuit breaker turned off.
It is recommended that a qualified electrician is consulted or used for the
installation of this Programmer and install in accordance with the current
IEE wiring and Building Regulations.
Check that the total load on the circuit including when this Programmer is
fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
To clean use a clean dry cloth only. Do not use any liquid cleaners.
3. Technical Specifications
230V AC 50 Hz
This thermostat is of Class ll Construction and must not be earthed
Switch Rating: 3(1)A
Switch Type: Single pole, double throw (SPDT)
for both heating and hot water,
change over contacts
Connection Type: 3 wire
Installation Type: Surface mount with wall plate
Micro Disconnection: Type 1.B control action
Operating Temperature Range: 0°C to +40°C
Programme: 5 day plus 2, or 7 day set by DIP switches
Pumped or Gravity Operation: System P or System G set by DIP switches
Time Control Periods: 3 per day with copy function
Clock Format: 12 hour AM/PM or 24 hour
Summer/Winter Changeover: Day light saving, GMT or BST
Holiday Mode: 0 to 31 day program suspension
Boost Function: 1, 2 or 3 hour for both heating
and hot water