Wiring definition 2.3
Below is the standard wiring definition of the actuator. If your actuator is ordered with customized wiring,
please contact TiMOTION sales for detailed information.
Limitations for limit switches output signals 2.3.1
In general, the MA2 cable can have a maximum of 6 pins (2 power wire pins and/or up-to 4 signal wire pins)
The function limitations for limit switches to output signals are shown in the table below:
Function for limit switches
Signal output
Without
POT
Single Hall
Double Hall
2 limit switches to cut the current
OK
2.3.2
OK
2.3.7
OK
2.3.5
OK
2.3.6
2 limit switches to cut the current
one additional limit switch for signal
output
OK
2.3.3
OK
2.3.8
x
x
2 limit switches for signal output
and cut current
OK
2.3.4
x
x
x
* OK = Selectable