2-30
Chapter 2
INDICATOR STATUS OF REMOTE MICROPHONES
2.14.IndicatorStateattheTimeofEmergencySequencePhaseShift
When the system is set to "Emergency" and the type of the RM-300X to "Emergency" or "Emergency/General,"
the emergency sequence phase shift function can be assigned to a function key.
Assigning this function to the Function key causes the 2 indicators next to the Function key to indicate the
emergency sequence phase state.
Notes
• Fortheemergencyfunctionsettings,seetheseparateSettingSoftwareInstructions,"BASICSETTINGS."
• ForthetypeoftheRM-300Xsettings,seetheseparateSettingSoftwareInstructions,"UnitConguration
Settings."
• For instructions on assigning functions to function keys, see the separate Setting Software Instructions,
"EVENT SETTINGS."
Phase State Indicator
Key ON/OFF Indicator
Function key (Phase shift key)
The meanings of the 2 indicators next to the Function key are as follows:
Indicator Status Meaning
Key ON/OFF Indicator Unlit
When the function key is not pressed
Lights green
When the function key is pressed (as long as it is pressed)
Phase State Indicator Lights green
Emergency sequence Phase 1 is assigned to the function
key.
Flashes green
Emergency sequence Phase 2 is assigned to the function
key.
Unlit
Emergency sequence Phase 3 is assigned to the function
key.