7.5. Example of communication
When set to the 50.00 for Higher and 40.00 for lower limit torques
Adjust the decimal point depend on the model and unit of measure.
Example 1) Set to 20 Nm for higher and 15 Nm for lower limit for CEM20N3X10D-G-BTA
Send a command the “AT037,20.00,15.00CRLF
Example 2) Set to 90 Nm for higher, 80 Nm for lower limit for CEM100N3X15D-G-BTA
Send a command the “AT037,090.0,080.0CRLF
Example 3) Set to 600 Nm for higher, 500 Nm for lower limit for CEM850N3X32D-G-BTA
Send a command the “AT037,0600.,0500.CRLF
When set to the 15 degrees for double tightening detection, 30 degrees for lower and
100 degrees for higher limit angles
External device
A T 0 3 7 , 5 0 . 0 0 , 4 0 . 0 0
CR LF
CEM3-BTA
R E 0 0 3 , O K
CR LF
Hi/Lo limit torques
Response command
Double tightening
detection angle and
Hi/ Lo limit angles
Response command
External device CEM3-BTA
R E 0 0 3 , O K
CR LF
A T 0 4 6 , 0 1 5 , 0 3 0 , 1 0 0
CR LF